栏目导航
navigation
日本TACO/AZBIL调压阀RVD-520YF-HLTT
发布时间:2024-07-10
日本TACO/AZBIL调压阀RVD-520YF-HLTT
R31 SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| RELIEF | Relieving and Non-relieving |
| ADJUSTMENT | Snap lock knob type (one touch lock) |
RK-1206 SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air | |
| MAXIMUM INLET PRESSURE | 1.0MPa | |
| AMBIENT TEMPERATURE | 5 ~ 60°C | |
| ADJUSTING PRESSURE RANGE | •0.02 ~ 0.8MPa •0.01 ~ 0.4MPa | |
| RELIEF | Relieving | |
| PIPE SIZE | Inlet port (common) | Rc3/4 at both sides |
| Outlet port | Rc1/2 at each regulator | |
| Gauge port | Rc1/8 at each regulator | |
NRV-300, 200 SERIES

SPECIFICATIONS
| SERIES | NRV-300 | NRV-200 |
| FLUID | Filtered Compressed Air | |
| MAXIMUM INLET PRESSURE* | 1.0MPa | |
| AMBIENT TEMPERATURE | 5 ~ 60°C | |
| OPERATION | Directly operated by spring | |
| ADJUSTING PRESSURE RANGE | •0.02 ~ 0.8MPa (Std.) •0.01 ~ 0.3MPa •0.01 ~ 0.1MPa •0.1 ~ 1.6MPa * | |
| RELIEF | Relieving | Non-relieving |
* Max Inlet pressure: 2.8MPa for units of ~1.6MPa range.
* 0.1~1.6MPa range is available for units of pipe size of 1/4,3/8 and 1/2.
BASIC MODEL NOs. & OTHERS
| Pipe Size | MODEL NUMBER | Gauge Port | Mass(kg) | |
| Relieving | Non-relieving | |||
| Rc1/4 | NRV-302 | NRV-202 | Rc1/8 (2 places) | 1.2 |
| Rc3/8 | NRV-303 | NRV-203 | ||
| Rc1/2 | NRV-304 | NRV-204 | 1.4 | |
| Rc3/4 | NRV-306 | NRV-206 | 2.9 | |
| Rc1 | NRV-310 | NRV-210 | 2.7 | |
NRV-400 SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Integral pilot operated type (Internal pilot type) |
| ADJUSTING PRESSURE RANGE | •0.02 ~ 0.7MPa (Std.) •0.01 ~ 0.4MPa •0.01 ~ 0.2MPa •0.1 ~ 1.6MPa* |
| RELIEF | Relieving and Non-relieving |
* Max Inlet pressure is 2.8MPa in case of units of 0.1~1.6MPa range.
BASIC MODEL NOs. & OTHERS
| Pipe Size | MODEL NUMBER | Adjusting Pressure Range | Gauge Port | Mass (kg) |
| Rc1/2 | NRV-404 | 0.2 ~ 0.7Mpa | Rc1/8 (2 places) | 1.7 |
| NRV-404K4 | 0.01 ~ 0.4Mpa | |||
| NRV-404K2 | 0.01 ~ 0.2Mpa | |||
| Rc3/4 | NRV-406 | 0.02 ~ 0.7Mpa | 3.1 | |
| NRV-406K4 | 0.01 ~ 0.4Mpa | |||
| Rc1 | NRV-410 | 0.02 ~ 0.7Mpa | 3.0 | |
| NRV-410K4 | 0.01 ~ 0.4Mpa |
RVD-400YF SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Integral pilot operated type (Internal pilot type) |
| ADJUSTING PRESSURE RANGE | 0.02 ~ 0.8MPa |
| RELIEF | Relieving and Non-relieving |
NRV-500 SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Remote controlled type (External pilot operated type) |
| OUTLET PRESSURE ADJUSTING RANGE | 0.02 ~ 0.8MPa (within the limits of pilot regulator) |
| RELIEF | Relieving and Non-relieving |
RVD-500YF SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Remote controlled type (External pilot type) |
| ADJUSTING PRESSURE RANGE | 0.02 ~ 0.8MPa |
| RELIEF | Relieving and Non-relieving |
R50 SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air Use air filter with 5μm element. |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Integral Feed-back pilot operated (Internal Pilot type) |
| ADJUSTING PRESSURE RANGE | 0.05 ~ 0.8MPa |
| RELIEF | High-relieving |
| STANDARD EQUIPPED PART | Bracket and Adapter for connecting pressure gauge |
R50-R SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Feed-Back Pilot Remote control type (External Pilot operated type) |
| ADJUSTING PRESSURE RANGE | 0.05 ~ 0.8MPa Depends on adjusting pressure range of pilot regulator. |
| RELIEF | High-relieving |
| EQUIPPED PART WITH STANDARD MODEL | Bracket and Adapter for connecting pressure gauge |
R50-M SERIES

SPECIFICATIONS
| FLUID | Filtered Compressed Air |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| OPERATION | Remote controlled type (External Pilot operated type) |
| ADJUSTING PRESSURE RANGE | 0.05 ~ 0.8MPa Depends on adjusting pressure range of pilot regulator. |
| RELIEF | High-relieving |
| EQUIPPED PART WITH STANDARD MODEL | Bracket and Adapter for connecting pressure gauge |
NRV-802 SERIES

SPECIFICATIONS
| MODEL NUMBER | NRV-802 | NRV-802K16 | NRV-802K4 | NRV-802K2 |
| PIPE SIZE | Rc1/4 | |||
| FLUID | Filtered Clean Air (Use 25μm filter element) | |||
| MAXIMUM INLET PRESSURE* | 1.0MPa | |||
| AMBIENT TEMPERATURE | 5 ~ 60°C | |||
| ADJUSTING PRESSURE RANGE | 0.02 ~ 0.7MPa | 0.1 ~ 1.6MPa | 0.01 ~ 0.4MPa | 0.01 ~ 0.2MPa |
| OPERATION | Directly operated and constant bleed type | |||
| RELIEF | Relieving type | |||
| GAUGE PORT | Rc1/8 | |||
| MASS (kg) | 0.84 | |||
* Max. inlet pressure is 2.8MPa in case of 0.1~1.6MPa range (K16).
NRV-802D SERIES

SPECIFICATIONS
| MODEL NUMBER | NRV-802D |
| PIPE SIZE | Rc1/4 (IN, OUT Port) |
| FLUID | Filtered Clean Air (w/5μm element) |
| MAXIMUM INLET PRESSURE | 1.0MPa |
| AMBIENT TEMPERATURE | 5 ~ 60°C |
| FEED BACK PORT | Rc 1/8 |
| MASS (kg) | 0.95 |
* For panel mount, add “P” at the end of model no.
Note: This regulator is used only as pilot regulator. In this case, master regulator recommended is R50-M series high relieving type.